Emergency Lights
An emergency light is a lighting device with a battery backup that switches on automatically when a building experiences a power outage. Emergency lights are standard in commercial and high occupancy residential buildings, such as college dormitories. Most building codes require emergency lighting be installed in older buildings as well.
White
The main housing of these exit signs and emergency lights is painted white or made from a white thermoplastic.
Black
The main housing of these exit signs and emergency lights is painted black or made from a black thermoplastic.
Sealed Lead Acid (SLA)
Sealed lead acid batteries are sometimes referred to as VRLA (valve regulated lead acid) and there are two primary types AGM and Gel. We offer both AGM and Gel batteries, each has its advantages over the other depending on the specific application. SLA batteries usually last between 3 to 5 years with typical usage. The optimum operating temperature for the lead-acid battery is 25°C (77°F). Elevated temperature reduces longevity. As a guideline, every 8°C (15°F) rise in temperature cuts the battery life in half.
Nickel-Cadmium (NiCd)
The nickel–cadmium battery is a type of rechargeable battery using nickel oxide hydroxide and metallic cadmium as electrodes. The abbreviation NiCd is derived from the chemical symbols of nickel and cadmium. NiCd batteries have a longer shelf life of around 10 years. The NiCd batteries sold on this site are High Temperature NiCds batteries with outstanding charge/discharge characteristics at both room temperature and high temperature up to 70°C (158°F).
Warning: Batteries, battery terminals, and related accessories can expose you to chemicals including Cadmium and Cadmium compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to
https://www.p65warnings.ca.gov.
Damp Location
A damp location is an interior location normally subject to dampness or condensation, or an exterior location protected from weather and not subject to saturation with water. Damp locations include over bathtubs, indoor pools, covered porches, and like locations.
New York City Approved
New York City has very specific codes regarding emergency lighting and signage. In short New York City approved exit signs must be Red 8 inch tall letters with a 1 inch stroke (line thickness) as opposed to 6 inch tall with a 3/4 inch stroke in typical exit signs.
Cold Weather
Batteries placed in cold environments can eventually fail or rupture. If your emergency lights or exit signs will be installed in temperatures below 20° F (-6° C), you may want to consider a cold weather option. Cold weather lights include a thermostatic battery heater which maintains the battery strength and lifespan in temperatures between -4° F (-20° C) and -40° F (-40° C) depending on the model you choose.
Buy America Compliant (BAA)
Products displaying an 'Assembled in the USA' label will contain a percentage of imported components but will be physically assembled in America and are compliant with the Buy American Act (BAA). The FTC states that Assembled in America products must have undergone a significant transformation on American soil.
Chicago Approved
Chicago Approved exit signs must meet specific rules and guidelines. Signs must be rectangular 20 gauge sheet metal with a glass or plastic face. The letters and arrows must be red on white. All exit signs must be internally illuminated with at least a 10 watt lamp.
Self-Testing
This feature may be added to many exit sign and emergency light fixtures, the SDT feature prolongs battery life, and reduced man hours required OSHA tests. Self testing diagnostic automatically executes a 15 minute test every 30 days and runs a 90 minutes test once per year. The major reasons batteries typically fail is because they remain dormant for long periods of time. With the SDT feature automatically simulates a full discharge and full recharge to keep the batteries in peak performance. If any problems arise during this testing process it will report them through the user interface. This benefit drastically reduces man hours required by OSHA to manually perform the tests.
LED Lighting
Visibility, brightness and long life are very important factors that should be thought about when purchasing and exit sign. Light emitting diode or LED exit signs & emergency lights have proven to be successful in the reducing electricity consumption by up to 85%. LED exit signs can save money and power while still emitting considerable amounts of light.
Internal Heater
Products with internal heater option allow the units and batteries to operate properly at temperatures down to -50°C.
Outdoor
Outdoor lighting is lighting used to illuminate the areas, where there are no roofs, i.e., outdoor areas. Outdoor lights are able to be in the elements of including rain and cold weather.
Surface/Wall Mount
Exit signs & emergency lights that are surface mountable are typically one sided and have a back plate that can be connected directly to a wall or flat surface.
Other Colors
With some products you can order your products with a custom color of your choosing. Custom color usually come with a longer lead time and we often need to contact the supplier for a final price for the customization.
Steel
Steel emergency lights and exit signs are designed to provide illumination and guidance in case of a power outage or an emergency situation. They are typically used in applications where steel housing is required for durability, protection, or aesthetics.
Some examples of where to use steel emergency lights and exit signs are:
Offices, factories, and warehouses: These places may have harsh environments or heavy machinery that can damage plastic or aluminum fixtures. Steel emergency lights and exit signs can withstand impacts, vibrations, and corrosion better than other materials.
Dual Circuit
Dual circuit exit signs. These unit allows the fixture to have dual power feeds. The idea behind this is so that when on normal power, the fixture is fed from a switch leg and can be turned off by the occupant. The PTS relay coil is fed by unswitched normal power. The normal power from the switch leg is connected to the normally open contacts on the PTS relay.
Architectural
Architectural lighting is designed to be a highly functional style of lighting in spaces where light fixtures are needed to serve a fundamental purpose, such as providing focused downlight or accenting certain areas of a room. Often thought of as a practical type of lighting, these fixtures are not usually given credit for their decorative character and ability to add undeniable style to a lighting project.
Commercial
Commercial lighting is lighting used for commercial spaces such as offices, stores, institutions, hospitals and government buildings, essentially those spaces that are not residential, industrial or for manufacturing.
Sanitation Listed
Sanitation Listed
PAR36