Z Hazardous Location Emergency Light

   5.00/1 Customer Review

Z Hazardous Location Emergency Light
Z Hazardous location emergency light units are suitable for use in Class I, Division 2, Groups A, B, C & D, Zone 2, Groups IIA, IIB + H2 & IIC and Class II, Division 2, Groups F & G.












Base SKU: Z
Weight: 18 lb
Suitable for use in Class I, Division 2, Groups A, B, C & D, Zone 2, Groups IIA, IIB + H2 & IIC and Class II, Division 2, Groups F & G.
 
CONSTRUCTION
  • Impact-resistant, fiberglass reinforced polyester housing. Gray with stainless steel hardware. View-through window allows easy monitoring of AC indicator and optional voltmeter and ammeter.
  • Lamp heads are Class I, Div. 2 rated polycarbonate sealed beam PAR36 tungsten or halogen lamps.
 
OPTICS — Halogen and incandescent lamp types available for both 6V and 12V units.
 
ELECTRICAL
  • 120/277 VAC dual-voltage input with surge-protected, solid-state charging circuitry. Low-voltage disconnect (LVD) feature disconnects battery prior to unacceptable deep discharge, but not before the required 90-minute emergency operation.
  • AC lockout prevents battery drain prior to energizing of utility power. Wiring and electrical connections can be completed without energizing emergency circuit.
  • Brownout protection circuitry automatically switches unit into emergency mode if utility voltage drops below 25% of nominal.
  • BATTERY: Choice of sealed, maintenance-free lead-calcium battery or sealed, maintenance-free nickel cadmium battery. 90-minute emergency operation at full light output. Battery charging circuitry utilizes constant-current charger for nickel-cadmium battery units. Fully automatic, voltage-regulated charger used for lead-calcium battery units. Battery recharge time after full discharge less than required by UL 924 standard.
  • DIAGNOSTICS: Self-diagnostic option conducts automatic and manual tests, indicating real time status of lamp, battery and charger via tri-color indicator lamps. Automatic tests include systems analysis every 10 seconds, with actual load tests performed for a one-minute duration every 30 days, and for a 30-minute duration on the sixth and twelfth month. Manual tests include a one-minute or 90-minute battery discharge and lamp illumination tests.
 
INSTALLATION
Wall mount only (optional mounting feet included).
 
LISTING
UL Listed. Meets UL 924 and UL 844 illumination standards. NFPA 101, NEC, OSHA and IBC illumination standards. Temperature class rating 160°C (T-Code T3C) or for Class I, Zone 2 rating is 200°C (T-Code T3).
 
WARRANTY
3-year limited warranty.